Product Description

PRODUCT DETAILS

 

 

7IK750A-AF 750W 110V 50HZ/60HZ Single Phase AC Induction Motor

Our company focuses on the production of Micro, Compact and Large AC Geared Motors, Permanent Magnet Brushed DC Motors, Stepper Motors, Servo Motors, High-precision Planetary Reducers, Hypoids, Speed Controllers, Inverters, etc.; Products can be independently combined, matched, and diversified solutions according to your demands.

 

Our products are widely used in various industrial assembly lines, intelligent equipment, animal husbandry machinery, printing machinery, textile machinery, instrumentation, food machinery, power transmission and transformation equipment, gate machines, medical equipment, logistics equipment, security inspection facilities, financial equipment, New energy, industrial robots and other industries.

 

If you can not find suitable models on our shop, please feel free to send your detailed demands, we will suggest the most suitable models for you.

 

Motor Specifications

Motor Type Motor Model Power Voltage Frequency Current Starting
Torque
Rated Torque Rated Speed Rated Time Capacitor
Motor with Round Shaft Motor with Gear Shaft W V Hz A N.m N.m RPM min μF/VAC
Induction Motor 7IK750A-AF 7IK750GN-AF 750 1PH110 50 9.7 8.57 5.04 1400 Continuous 80/250
60 9.7 7.16 4.21 1680 Continuous 80/250
7IK750A-CF 7IK750GN-CF 750 1PH220 50 4.85 8.57 5.04 1400 Continuous 24/450
60 4.85 7.16 4.21 1680 Continuous 24/450
7IK750A-SF 7IK750GN-SF 750 3PH220 50 3.64 11.78 5.12 1400 Continuous /
60 3.64 9.8 4.26 1680 Continuous /
7IK750A-UF 7IK750GN-UF 750 3PH380 50 2.10  11.78 5.12 1400 Continuous /
60 2.10  9.8 4.26 1680 Continuous /
Reversibal Motor 7RK750A-AF 7RK750GN-AF 750 1PH110 50 9.7 8.57 5.04 1400 30 80/250
60 9.7 7.16 4.21 1680 30 80/250
7RK750A-CF 7RK750GN-CF 750 1PH220 50 4.85 8.57 5.04 1400 30 24/450
60 4.85 7.16 4.21 1680 30 24/450
Brake Motor 7IK750A-AFM 7IK750GN-AMF 750 1PH110 50 9.7 8.57 5.04 1400 30 80/250
60 9.7 7.16 4.21 1680 30 80/250
7IK750A-CFM 7IK750GN-CMF 750 1PH220 50 4.85 8.57 5.04 1400 30 24/450
60 4.85 7.16 4.21 1680 30 24/450
7IK750A-SFM 7IK750GN-SFM 750 3PH220 50 3.64 11.78 5.12 1400 Continuous /
60 3.64 9.8 4.26 1680 Continuous /
7IK750A-UFM 7IK750GN-UFM 750 3PH380 50 2.10  11.78 5.12 1400 Continuous /
60 2.10  9.8 4.26 1680 Continuous /
 
Motor Type Motor Model Power Voltage Frequency Speed Control Range Starting
Torque
Rated Torque
N.m
Rated Time Capacitor
Motor with Round Shaft Motor with Gear Shaft W V Hz RPM N.m 90RPM 1400RPM min μF/VAC
Speed Control Motor 7IK750RA-AF 7IK750RGU-AF 750 1PH110 50 90-1400 8.57 2.05 5.04 Continuous 80/250
60 90-1680 7.16 2.05 4.21 Continuous 80/250
7IK750RA-CF 7IK750RGU-CF 750 1PH220 50 90-1400 7.57 2.05 5.04 Continuous 25/450
60 90-1680 7.16 2.05 4.21 Continuous

25/450

 

 

Gearbox Ratio, Speed and Torque

Drawings

 

 

OUR ADVANTAGES

 

 

ACCESSORIES

 

APPLICATION

 

 

 

OUR FACTORY

 

 

Lunyee Industries Development Co., Ltd. is a leading manufacturer for factory automation (FA) products, we focus on power transmission and motion control solutions!

 

Our main production are power transmission products like AC and DC(brush/brushless) gear motor, stepper motor, high precision planetary gearbox (spur/helical gear) for stepping motor etc.

 

-WE FOCUS ON CUSTOMER SATISFACTION!

 

 

/* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

Application: Industrial
Speed: Constant Speed
Number of Stator: Single-Phase
Function: Driving
Casing Protection: Open Type
Number of Poles: 4
Samples:
US$ 116/Piece
1 Piece(Min.Order)

|

Customization:
Available

|

induction motor

Are there specific maintenance requirements for AC motors to ensure optimal performance?

Yes, AC motors have specific maintenance requirements to ensure their optimal performance and longevity. Regular maintenance helps prevent unexpected failures, maximizes efficiency, and extends the lifespan of the motor. Here are some key maintenance practices for AC motors:

  1. Cleaning and Inspection: Regularly clean the motor to remove dust, dirt, and debris that can accumulate on the motor surfaces and hinder heat dissipation. Inspect the motor for any signs of damage, loose connections, or abnormal noise/vibration. Address any issues promptly to prevent further damage.
  2. Lubrication: Check the motor’s lubrication requirements and ensure proper lubrication of bearings, gears, and other moving parts. Insufficient or excessive lubrication can lead to increased friction, overheating, and premature wear. Follow the manufacturer’s guidelines for lubrication intervals and use the recommended lubricants.
  3. Belt and Pulley Maintenance: If the motor is coupled with a belt and pulley system, regularly inspect and adjust the tension of the belts. Improper belt tension can affect motor performance and efficiency. Replace worn-out belts and damaged pulleys as needed.
  4. Cooling System Maintenance: AC motors often have cooling systems such as fans or heat sinks to dissipate heat generated during operation. Ensure that these cooling systems are clean and functioning properly. Remove any obstructions that may impede airflow and compromise cooling efficiency.
  5. Electrical Connections: Regularly inspect the motor’s electrical connections for signs of loose or corroded terminals. Loose connections can lead to voltage drops, increased resistance, and overheating. Tighten or replace any damaged connections and ensure proper grounding.
  6. Vibration Analysis: Periodically perform vibration analysis on the motor to detect any abnormal vibrations. Excessive vibration can indicate misalignment, unbalanced rotors, or worn-out bearings. Address the underlying causes of vibration to prevent further damage and ensure smooth operation.
  7. Motor Testing: Conduct regular motor testing, such as insulation resistance testing and winding resistance measurement, to assess the motor’s electrical condition. These tests can identify insulation breakdown, winding faults, or other electrical issues that may affect motor performance and reliability.
  8. Professional Maintenance: For more complex maintenance tasks or when dealing with large industrial motors, it is advisable to involve professional technicians or motor specialists. They have the expertise and tools to perform in-depth inspections, repairs, and preventive maintenance procedures.

It’s important to note that specific maintenance requirements may vary depending on the motor type, size, and application. Always refer to the manufacturer’s guidelines and recommendations for the particular AC motor in use. By following proper maintenance practices, AC motors can operate optimally, minimize downtime, and have an extended service life.

induction motor

What are the common signs of AC motor failure, and how can they be addressed?

AC motor failure can lead to disruptions in various industrial and commercial applications. Recognizing the common signs of motor failure is crucial for timely intervention and preventing further damage. Here are some typical signs of AC motor failure and potential ways to address them:

  • Excessive Heat: Excessive heat is a common indicator of motor failure. If a motor feels excessively hot to the touch or emits a burning smell, it could signify issues such as overloaded windings, poor ventilation, or bearing problems. To address this, first, ensure that the motor is properly sized for the application. Check for obstructions around the motor that may be impeding airflow and causing overheating. Clean or replace dirty or clogged ventilation systems. If the issue persists, consult a qualified technician to inspect the motor windings and bearings and make any necessary repairs or replacements.
  • Abnormal Noise or Vibration: Unusual noises or vibrations coming from an AC motor can indicate various problems. Excessive noise may be caused by loose or damaged components, misaligned shafts, or worn bearings. Excessive vibration can result from imbalanced rotors, misalignment, or worn-out motor parts. Addressing these issues involves inspecting and adjusting motor components, ensuring proper alignment, and replacing damaged or worn-out parts. Regular maintenance, including lubrication of bearings, can help prevent excessive noise and vibration and extend the motor’s lifespan.
  • Intermittent Operation: Intermittent motor operation, where the motor starts and stops unexpectedly or fails to start consistently, can be a sign of motor failure. This can be caused by issues such as faulty wiring connections, damaged or worn motor brushes, or problems with the motor’s control circuitry. Check for loose or damaged wiring connections and make any necessary repairs. Inspect and replace worn or damaged motor brushes. If the motor still exhibits intermittent operation, it may require professional troubleshooting and repair by a qualified technician.
  • Overheating or Tripping of Circuit Breakers: If an AC motor consistently causes circuit breakers to trip or if it repeatedly overheats, it indicates a problem that needs attention. Possible causes include high starting currents, excessive loads, or insulation breakdown. Verify that the motor is not overloaded and that the load is within the motor’s rated capacity. Check the motor’s insulation resistance to ensure it is within acceptable limits. If these measures do not resolve the issue, consult a professional to assess the motor and its electrical connections for any faults or insulation breakdown that may require repair or replacement.
  • Decreased Performance or Efficiency: A decline in motor performance or efficiency can be an indication of impending failure. This may manifest as reduced speed, decreased torque, increased energy consumption, or inadequate power output. Factors contributing to decreased performance can include worn bearings, damaged windings, or deteriorated insulation. Regular maintenance, including lubrication and cleaning, can help prevent these issues. If performance continues to decline, consult a qualified technician to inspect the motor and perform any necessary repairs or replacements.
  • Inoperative Motor: If an AC motor fails to operate entirely, there may be an issue with the power supply, control circuitry, or internal motor components. Check the power supply and connections for any faults or interruptions. Inspect control circuitry, such as motor starters or contactors, for any damage or malfunction. If no external faults are found, it may be necessary to dismantle the motor and inspect internal components, such as windings or brushes, for any faults or failures that require repair or replacement.

It’s important to note that motor failure causes can vary depending on factors such as motor type, operating conditions, and maintenance practices. Regular motor maintenance, including inspections, lubrication, and cleaning, is essential for early detection of potential failure signs and for addressing issues promptly. When in doubt, it is advisable to consult a qualified electrician, motor technician, or manufacturer’s guidelines for appropriate troubleshooting and repair procedures specific to the motor model and application.

induction motor

What are the main components of an AC motor, and how do they contribute to its operation?

An AC motor consists of several key components that work together to facilitate its operation. These components include:

  1. Stator: The stator is the stationary part of an AC motor. It is typically made of a laminated core that provides a path for the magnetic flux. The stator contains stator windings, which are coils of wire wound around the stator core. The stator windings are connected to an AC power source and produce a rotating magnetic field when energized. The rotating magnetic field is a crucial element in generating the torque required for the motor’s operation.
  2. Rotor: The rotor is the rotating part of an AC motor. It is located inside the stator and is connected to a shaft. The rotor can have different designs depending on the type of AC motor. In an induction motor, the rotor does not have electrical connections. Instead, it contains conductive bars or coils that are short-circuited. The rotating magnetic field of the stator induces currents in the short-circuited rotor conductors, creating a magnetic field that interacts with the stator field and generates torque, causing the rotor to rotate. In a synchronous motor, the rotor contains electromagnets that are magnetized by direct current, allowing the rotor to lock onto the rotating magnetic field of the stator and rotate at the same speed.
  3. Bearing: Bearings are used to support and facilitate the smooth rotation of the rotor shaft. They reduce friction and allow the rotor to rotate freely within the motor. Bearings are typically located at both ends of the motor shaft and are designed to withstand the axial and radial forces generated during operation.
  4. End Bells: The end bells, also known as end covers or end brackets, enclose the motor’s stator and rotor assembly. They provide mechanical support and protection for the internal components of the motor. End bells are typically made of metal and are designed to provide a housing for the bearings and secure the motor to its mounting structure.
  5. Fan or Cooling System: AC motors often generate heat during operation. To prevent overheating and ensure proper functioning, AC motors are equipped with fans or cooling systems. These help dissipate heat by circulating air or directing airflow over the motor’s components, including the stator and rotor windings. Effective cooling is crucial for maintaining the motor’s efficiency and extending its lifespan.
  6. Terminal Box or Connection Box: The terminal box is a housing located on the outside of the motor that provides access to the motor’s electrical connections. It contains terminals or connection points where external wires can be connected to supply power to the motor. The terminal box ensures a safe and secure connection of the motor to the electrical system.
  7. Additional Components: Depending on the specific design and application, AC motors may include additional components such as capacitors, centrifugal switches, brushes (in certain types of AC motors), and other control devices. These components are used for various purposes, such as improving motor performance, providing starting assistance, or enabling specific control features.

Each of these components plays a crucial role in the operation of an AC motor. The stator and rotor are the primary components responsible for generating the rotating magnetic field and converting electrical energy into mechanical motion. The bearings ensure smooth rotation of the rotor shaft, while the end bells provide structural support and protection. The fan or cooling system helps maintain optimal operating temperatures, and the terminal box allows for proper electrical connections. Additional components are incorporated as necessary to enhance motor performance and enable specific functionalities.

China supplier 7ik750gn-Af 750W 110V 50Hz/60Hz Single Phase AC Induction Gear Motor   vacuum pump ac system	China supplier 7ik750gn-Af 750W 110V 50Hz/60Hz Single Phase AC Induction Gear Motor   vacuum pump ac system